GET A QUICK SOLAR QUOTE

Battery Backup Systemssolar components - archive

Ritar 2Volt 1500Ah GEL Deep Cycle Battery

 

Ritar DG series is special for cyclic discharge applications use. This series is adopted pure Si02 with Calcium tin thicker plate, when under cycle discharge, it will deliver out longer cycle life, minimal gassing even under extreme temperature.

 

Applications

 

  • Electric plant
  • Wheel Chair
  • Solar Photovoltaic
  • Cleaning Machine
  • Wind System
  • Mower, RV, caravan motor home
  • Marine Boat

Warranty

 

  • 3 Years Warranty

Technical Specifications

 

Electrical Characteristics
Cells Per Unit 1
Voltage Per Unit 2
Capacity 1500Ah at 10hr rate to 1.75 per cell at 25ºC
Max. Discharge Current 4000A (5 sec)
Internal Resistance 06 mΩ
Operating Temperature Range Discharge: -20ºC to 60ºC
Charge: 0ºC to 50ºC
Storage: -20ºC to 60ºC
Normal Operating Temperature Range 25ºC ± 5ºC
Float charging Voltage 2.25 to 2.30 VDC/unit average at 25ºC
Recommended maximum charging current limit 300A
Equalization and Cycle Service 2.40 to 2.45 VDC/unit average at 25ºC
Self Discharge RITAR batteries can be stored for more than 6 months at 25ºC. Please charge batteries before using. For higher temperature, the time interval will be shorter.
Mechanical Characteristics
Dimensions 407L x 353W x 383H mm
Weight 100 kg
Terminal Threat insert and Bolt F10

Constant Current Discharge Characteristics Unit: A 25ºC

 

F.V/Time 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 10HR
1.60 V 2025 1423 872 536 399 318 268 232 187 156
1.65 V 1925 1366 834 516 382 307 257 226 179 151
1.70 V 1795 1288 818 508 374 304 254 220 176 148
1.75 V 1594 1145 753 480 354 287 243 209 170 145
1.80 V 1372 1056 710 458 340 285 234 206 167 140
1.85 V 1160 950 656 432 324 262 223 195 159 134

Constant Power Discharge Characteristics Unit: W 25ºC

 

F.V/Time 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 6HR 8HR 10HR
1.60 V 3545 2530 1558 968 725 583 494 438 349 296
1.65 V 3511 2516 1553 954 723 578 488 432 346 293
1.70 V 3231 2341 1504 940 700 569 483 424 340 290
1.75 V 2904 2109 1404 898 675 550 463 405 332 282
1.80 V 2499 1944 1323 859 638 533 449 396 321 273
1.85 V 2114 1752 1220 809 617 491 430 374 307 265

Charging Procedures - 2V Series

 

Application Charge Voltage Max Charge Current
Temperature Set point Allowable range
Cycle Use 25ºC 2.45 2.4 - 2.5 0.3C
Standby 25ºC 2.28 2.26 - 2.3 0.3C

Charging Procedures - 2V Series

 

Application Charge Voltage Max Charge Current
Temperature Set point Allowable range
Cycle Use 25ºC 2.275 2.25 - 2.30 0.3C
Standby 25ºC 2.425 2.4 - 2.45 0.3C

Discharge Current VS Discharge Voltage

 

Final Discharge Voltage V/cell 1.75 V 1.70 V 1.60 V
Discharge Current A (A) ≤ 0.2C 0.2C < (A) < 1.0C (A) ≥ 1.0C

Quality and Safety

 

  • Comply with ISO9001:2000 Certificate
  • EMC tested Germany
  • G4M20206-0910-E-16

Details

  • Model: RL2 1500DG
  • Shipping Weight: 100kg
  • Manufacturer:
    Ritar